Compare free quotes from local and nationwide heat pump installers...

Dimplex Air Source Heat Pumps

Dimplex is a leading developer of electric space and water heating solutions based in the UK.

The company offers eight ranges of air source heat pumps to meet your domestic heating needs.

LA MAS

Comes in two single phase models:

LA 11 MAS – 11kW, CoP 3.7 to 3.9
LA 16 MAS – 16kW, CoP 3.7 to 3.9

The LA MAS range of air source heat pumps are installed outdoors, so minimal indoor space is required. They’re suitable for use with underfloor heating, radiator systems and to provide domestic hot water.

Variable heating water flow temperatures are from 35 degrees Celsius to 55 degrees Celsius, and the operational temperatures are from minus 20 degrees Celsius to 35 degrees Celsius plus.

Products are supplied complete with a wall mounted WPM heat pump manager and feature an auto defrost cycle.

LA MI

Comes in four single phase models:

LA 6 MI – 6kW, CoP 4.4
LA 9 MI – 9kW, CoP 4.1
LA 12 MI – 12kW, CoP 4.67
LA 16 MI – 16kW, CoP 4.23

LA MI air source heat pumps are installed outdoors and utilise resistant stainless steel to protect against corrosion. These appliances are suitable for underfloor heating, radiator systems and to provide domestic hot water.

Variable heating water flow temperatures are from 25 degrees Celsius to 55 degrees Celsius, and the operational temperatures are from minus 20 degrees Celsius to 35 degrees Celsius plus.

Additional features include, fully integrated system components, low noise levels and a wall mounted inverter heat pump manager.

LA PMS

Comes in two single phase models:

LA 8 PMS – 8kW, CoP 3.7 to 3.9
LA 14 PMS – 14kW, CoP 3.7 to 3.9

LA PMS air pumps are installed outdoors and take advantage of an auto adaptive defrost cycle. These pumps are particularly environmentally friendly as they use R290 refrigernat (GWP of 3). LA PMS heat pumps are suitable for use with under floor heating, Dimplex SmartRad fan convection radiators, conventional radiator systems and domestic hot water production.

Variable heating water flow temperatures are from 35 degrees Celsius to 65 degrees Celsius, and the operational temperatures are from minus 25 degrees Celsius to 35 degrees Celsius plus.

These products also provide efficient sound insulation, a wall mounted WPM heat pump manager and intelligent switching between compressors to maximise compressor life.

LAB M

Comes in three single phase models:

LAB 7 M – 7kW, CoP 3.66
LAB 9 M – 9kW, CoP 3.66
LAB 11 M – 11kW, CoP 3.66

Designed for ease of installation outdoors. LAB M air source heat pumps are ideal for use with underfloor heating, radiator systems and domestic hot water.

Variable heating water flow temperatures are from 35 degrees Celsius to 58 degrees Celsius, and the operational temperatures are from minus 15 degrees Celsius to 25 degrees Celsius plus.

Additional features include frost protection, integrated system components, corrosion resistance, quite operation and a return flow water temperature regulator.

LA TU

Comes in six three phase models:

LA 9 TU – 9kW, CoP 4.4
LA 12 TU – 12kW, CoP 4.4
LA 17 TU – 17kW, CoP 4.4
LA 25 TU – 25kW, CoP 4.4
LA 40 TU – 40kW, CoP 4.4
LA 60 TU – 60kW, CoP 4.4

These are highly efficient air source heat pumps, for outdoor installation. Compatible with underfloor heating, radiator systems and to provide domestic hot water.

Variable heating water flow temperatures are from 35 degrees Celsius to 65 degrees Celsius, and the operational temperatures are from minus 25 degrees Celsius to 35 degrees Celsius plus.

Key features include intelligent load switching between compressors to maximise usage, side or under-unit entry for hydraulic/electrical connections and expansion options for bivalent or bivalent-renewable operating mode and distribution systems with mixed and unmixed heating circuits.

LA AS

Comes in three three phase models:

LA 20 AS – 20kW, CoP 3.1 to 3.6
LA 24 AS – 24kW, CoP 3.1 to 3.6
LA 28 AS – 28kW, CoP 3.1 to 3.6

LA AS models are designed for outdoor installation and are therefore protected against frost and corrosion. These air source heat pumps are made for use with radiator systems, underfloor heating and to provide domestic hot water.

Variable heating water flow temperatures are from 35 degrees Celsius to 55 degrees Celsius, and the operational temperatures are from minus 20 degrees Celsius to 35 degrees Celsius plus.

Additional features are extensive sound insulation, reduce running noise and a supplied wall mounted WPM heat pump manager.

LA PS

Comes in six three phase models:

LA 8 PMS – 8kW, CoP 3.4 to 3.8 (single phase)
LA 9 PS – 9kW, CoP 3.4 to 3.8
LA 11 PS – 11kW, CoP 3.4 to 3.8
LA 17 PS – 17kW, CoP 3.4 to 3.8
LA 22 PS – 22kW, CoP 3.4 to 3.8
LA 26 PS – 26kW, CoP 3.4 to 3.8

As these appliances are installed outdoors, minimal indoor space is required. LA PS appliances are suitable for use with underfloor heating, radiator systems and to provide domestic hot water.

Variable heating water flow temperatures from 35 degrees Celsius to 65 degrees Celsius, weather compensated. Operational temperatures from minus 20 degrees Celsius to 35 degrees Celsius plus.

Additional features include corrosion resistance, reduce sound levels and reduced starting current loads.

LA HS

Comes in two three phase models:

LA 22 HS – 22kW, CoP 3.4 to 3.8
LA 26 HS – 26kW, CoP 3.4 to 3.8

LA HS air source heat pumps are for outdoor installation. They are designed for use with underfloor heating, radiator systems and to provide domestic hot water.

Variable heating water flow temperatures from 35 degrees Celsius to 75 degrees Celsius, weather compensated. Operational temperatures from minus 20 degrees Celsius to 35 degrees Celsius plus.

Advantageous features include twin compressors for high capacity output and the ability to switch between compressors to maximise compressor life.

Compare free quotes from local and nationwide heat pump installers...

Leave a Reply